Resistivity / Hall Effect Package

Abbess Instruments Resistivity / Hall Effect Probes
Instrument package (IPACK-1)
     Voltage/Current Source
     Nanovoltmeter
     Relay Matrix

leadless sample carrier
The Resistivity / Hall Effect probes designed and built to fit any ABBESS cryostat, to allow the customer to measure resistance changes as small as 10-6 ohm. The probe has a theoretical sensitivity of about 10-8 ohm:

The probes can accept samples up to the limits of the cryostat used. The probes typically has a minimum of 4 contacts, but may have up to 256. The Instrument Packages' (IPACK-1) contains a voltage/current source that supplies current from 100 micro amp to 10.1 amp with an accuracy of ±(0.l % + 0.1 mA) at the low end and ±(0.5% + 10 mA) at the high end. The IPACK-l's nanovoltmeter can read from 10nV to 1000V with accuracies of ±(0.006% + 5nV) at the low end and ±(0.005% + 1.5V) at the high end. The IPACK-1 can interface with the optional system controller(computer).

General Technical Specifications
(Specifications may vary depending on final configuration)
Resistivity Measurement Sensitivity 10-7ohms or better; theoretical sensitivity 10-9 ohms
Uses quasi-DC measurement technique to avoid effects of sample inductance and capacitance while canceling thermal emf; complete measurements every 2 seconds over IEEE-488 bus
Range 10-7 to 2 ohms (optional to 1000 ohms)
Precision ±0.1%; accuracy (1 year) ±0.1% for R> 10-4 ohms; ±0.5% for 10-6< R < 10-4 ohms
Current Control Minimum current is 0.1 nA
Maximum current is 10.1 amp
Voltage Measurement Recommended Nanovoltmeter: 10 nV resolution, 5.5-6.5 digit resolution, ranges to 1000 V, IEEE-488 interface
Current/Voltage source Recommended Voltage/Current Source: 100 mA to 10 A or 1 V to 100 V full scale output with 3 digit resolution, 100 watts, IEEE-488 interface
Sample Environments (Dependent on Cryostat Used)
Cryostat CTC-1 Range: 4K to 925K
Stability: Dependent on temperature controller selected
Rate of Change: 300K to 77K in 5 minutes, 300K to 925K in 30 minutes
Sample environment is isolated from cryogen chamber allowing user to choose gases or vacuum which will be in contact with the sample
Sample Size: Up to .500 inch x 1.00 inch x .050 inch thick; max. electrical contacts 12
Cryostat CTC-2 Range: 1 0K to 1000K
Stability: Dependent on temperature controller selected
Rate of Change: 300K to 77K in 1 0 minutes, 300K to 800K in 30 minutes
Sample environment is isolated from cryogen chamber allowing user to choose gases or vacuum which will be in contact with the sample
Pressure: 10-6 Torr to 500 psig
Sample Size: Up to 1.00 inch x 2.00 inch x .500 inch thick; max. electrical contacts 24
Cryostat CTC-6 Range: 4K to 425K
Stability: Dependent on temperature controller selected
Sample plate is copper cold finger to minimize gradients
Cryostat is table or desk mountable
Sample Size: Up to 1 inch x 1.25 inch; max. electrical contacts 256

Faraday and Hall Measurement System

Back to top of Abbess Main Home Page
ASTM site map
If you have any questions, need custom configurations, or a quotation,
please e-mail us at

ABBESS, INC.

Mail Address: P.O. Box 498, Ashland, MA USA 01721-0498
Shipping Address: 70 Bartzak Drive, Holliston, MA USA 01746-1158

Phone: (508) 881-8811, FAX: (508) 881-4884
Toll Free: (800) 958-8886

ABBESS IS A TRADE MARK OF ABBESS , INC, ©2006 ABBESS.

Thursday, April 09, 2009